Ministry: WorkSafe New Zealand: Energy Safety
Section: 45(1)
Citation Context:
(1) All gasfitting work done on a gas installation or part installation must be tested... ...(d) in the case of a gas installation or part installation that does not comply with sections 3 to 6 of AS/NZS 5601.1 or sections 3 to 9 of AS/NZS 5601.2 (as applicable), in accordance with the verification or testing process set out in the certified design for the gas installation or part installation.
Ministry: WorkSafe New Zealand: Energy Safety
Section: Schedule 1
Citation Context:
AS/NZS 5601.2–2013: New Zealand Standard known as AS/NZS5601.2:2013 (Gas installations—Part 2: LP Gas installations in caravans and boats for non-propulsive purposes)
Ministry: WorkSafe New Zealand: Energy Safety
Section: 51(1)
Citation Context:
(1) Before a person connects a gas installation or part installation on which gasfitting work has been done to a gas supply, the person doing the connection or, if subclause (5) applies, the supervisor must... ...(g) if the gas installation or part installation is an imported gas installation or part installation, ensure that it complies with the requirements of section 2 of AS/NZS 5601.1 or section 2 of AS/NZS 5601.2 (as applicable).
Ministry: WorkSafe New Zealand: Energy Safety
Section: 44(1)
Citation Context:
(1) Every person who designs, installs, tests, commissions, or connects a gas installation or part installation must design, install, test, commission, and connect the gas installation or part installation in accordance with any applicable certified design and whichever of the following applies:... ...(b) AS/NZS 5601.2.
Ministry: WorkSafe New Zealand: Energy Safety
Section: 44(5)
Citation Context:
(5) For the purposes of subclauses (1) to (3)... ...(b) despite anything to the contrary in AS/NZS 5601.2, a gas installation does not fail to be a gas installation to which AS/NZS 5601.2 applies by reason only that it receives gas at a supply pressure of more than 3 kilopascals.
Ministry: WorkSafe New Zealand: Energy Safety
Section: 44(2)
Citation Context:
(2) If a gas installation or part installation does not comply with either sections 3 to 6 of AS/NZS 5601.1 or sections 3 to 9 of AS/NZS 5601.2, any person who installs, tests, commissions, or connects the installation or part installation must do so in accordance with a certified design.
Ministry: WorkSafe New Zealand: Energy Safety
Section: 5A(2)
Citation Context:
In these regulations, high-risk gasfitting means any of the following, unless it is low-risk gasfitting:... ...(b) any gasfitting, other than that described in paragraph (a), that... ...(vi) is carried out in accordance with AS/NZS 5601.2 where the operating pressure is greater than 3 kilopascals.
Ministry: WorkSafe New Zealand: Energy Safety
Section: 44(3)
Citation Context:
(3) Every person who supplies or intends to supply an imported gas installation to a retailer or consumer must, before supplying the gas installation, ensure that it complies with the requirements of section 2 of whichever of the following applies:... ...(b) AS/NZS 5601.2.
Ministry: WorkSafe New Zealand: Energy Safety
Section: 48(1)
Citation Context:
(1) Every certificate of compliance must record the following:... ...(a) whether the work has been done in accordance with sections 3 to 6 of AS/NZS 5601.1 or in accordance with sections 3 to 9 of AS/NZS 5601.2.... ...(c) if the work was required to comply with standards in addition to AS/NZS 5601.1 or AS/NZS 5601.2 (as applicable), which standards were complied with.