Ministry: Association of Rotational Moulders Australasia Inc
Section: 1.2
Citation Context:
In addition to the limitations stated in Section 1.2 of AS/NZS 4766, the following additional limitations apply to tanks designed, manufactured and installed using this code...
Ministry: WorkSafe New Zealand
Section: 19(b)
Citation Context:
If the integral secondary containment system is made of material that is not black in colour, the colouring material must be compounded into the polymer in a way that meets the ultraviolet light requirements of AS/NZS 4766.
Ministry: WorkSafe New Zealand
Section: 22
Citation Context:
Impact strength test: (1) A PCBU who constructs a tank must ensure that the impact strength test specified in table A1 of AS/NZS 4766 is performed on a tank (including its integral secondary containment system, if applicable).
Ministry: WorkSafe New Zealand
Section: Interpretation
Citation Context:
AS/NZS 4766 means the Australian/New Zealand standard AS/NZS 4766:2006 Polyethylene storage tanks for water and chemicals
Ministry: WorkSafe New Zealand
Section: 6
Citation Context:
Duties in respect of tank: (1) A relevant PCBU must ensure that a tank is designed, constructed, marked, and tested in accordance with AS/NZS 4766 and the provisions of this safe work instrument. (2) A PCBU with management or control of a tank must ensure that the tank is installed in accordance with AS/NZS 4766 and the provisions of this safe work instrument. (3) The provisions of AS/NZS 4766 are subject to the provisions of this safe work instrument.
Ministry: WorkSafe New Zealand
Section: 14(3)
Citation Context:
A relevant PCBU must ensure that the materials comply with paragraph 6.1 of AS/NZS 4766 and the following requirements:...
Ministry: WorkSafe New Zealand
Section: 20(1)
Citation Context:
A relevant PCBU must ensure that a tank is permanently and legibly marked with the following information by moulding the information into the outside surface of the tank:... ...(b) the information specified in clause 14 of AS/NZS 4766:...
Ministry: WorkSafe New Zealand
Section: Interpretation
Citation Context:
AS/NZS 4766 means the standard AS/NZS 4766:2006 Polyethylene storage tanks for water and chemicals
Ministry: WorkSafe New Zealand
Section: 21
Citation Context:
Polymer testing: A PCBU who constructs a tank must ensure that the polymer used in the construction of a tank (including its integral secondary containment system, if applicable) is subjected to a (a) light-penetration test performed as a material type test in accordance with AS/NZS 4766; and (b) dispersion test performed as a material quality control test in accordance with AS/NZS 4766.
Ministry: Association of Rotational Moulders Australasia Inc
Section: 1.1 Scope
Citation Context:
The purpose of this approved code of practice (Code) is to adopt the current requirements of AS/NZS 4766, with additional requirements for the design, manufacture and installation of above ground tanks constructed using the rotational moulding process and which are intended to contain non-flammable hazardous substances with class 5, 6, 8 and 9 classifications.
Ministry: Association of Rotational Moulders Australasia Inc
Section: 1.4
Citation Context:
AS/NZS 4766:2006 means the standard Polyethylene storage tanks for water and chemicals
Ministry: Association of Rotational Moulders Australasia Inc
Section: 2.5
Citation Context:
Minimum material properties are listed below with reference also made to Paragraph 6.1 of AS/NZS 4766 in this regard....
Ministry: Association of Rotational Moulders Australasia Inc
Section: 3.0
Citation Context:
In addition to the requirements of applicable local ordinances (In New Zealand, clause 77 (b) of Schedule 8 to the Hazardous Substances (dangerous Goods and Scheduled Toxic Substances) Transfer Notice 2044 (as amended)) and any marking requirements from AS/NZS 4766 – clause 14, the permanent markings on the outside of the tank are to include...