Ministry: WorkSafe New Zealand: Energy Safety
Section: 24(6)
Citation Context:
Where an RCD is required by AS/NZS 3000 to be installed to protect children from the risk of electric shockfrom direct contact, the RCD is deemed to be electrically unsafe if ...
Ministry: WorkSafe New Zealand: Energy Safety
Section: 60
Citation Context:
(1) A person who installs a domestic installation that has a maximum demand at or below 80 amperes single phase or 50 amperes per phase in multi-phase must ensure that the installation complies with Part 2 of AS/NZS 3000. (2) A person who installs any of
Ministry: WorkSafe New Zealand: Energy Safety
Section: 70
Citation Context:
(1) Prescribed electrical work that must be certified must also be inspected if it is any of the following: (a) work carried out in accordance with Part 1 of AS/NZS 3000:... ...(2) However, prescribed electrical work on low voltage railway signalling inst
Ministry: WorkSafe New Zealand: Energy Safety
Section: Schedule 2
Citation Context:
AS/NZS 3000 (means) AS/NZS 3000:2007: Electrical installations (known as the Australian/New Zealand Wiring Rules): including Amendments 1 and 2, subject to the following modifications....
Ministry: WorkSafe New Zealand: Energy Safety
Section: 61AA
Citation Context:
(2) This regulation applies despite anything in Part 1 or Part 2 of AS/NZS 3000.
Ministry: WorkSafe New Zealand: Energy Safety
Section: 59(1)
Citation Context:
This regulation applies to an installation, or part of any installation, that is being installed in accordance with Part 1 of AS/NZS 3000, despite anything in that Part.
Ministry: WorkSafe New Zealand: Energy Safety
Section: 4 Interpretation
Citation Context:
(3) A term used in these regulations and not defined in the Act or these regulations, and to which subclause (2) does not apply, has the meaning given (if any), (a) in the case of installations, in AS/NZS 3000; and ...
Ministry: WorkSafe New Zealand: Energy Safety
Section: 64(2)
Citation Context:
For the purposes of section 79(1)(a) of the Act, the domestic electrical wiring work that an owner of premises may do is as follows:... ...(b) installing, extending, and altering subcircuits (including submains), but only if... ...(ii) the work is tested
Ministry: WorkSafe New Zealand: Energy Safety
Section: Schedule 8, Clause 28
Citation Context:
(8) Coverings on cables must be protected against chemical corrosion in the manner provided for in AS/NZS 3000.
Ministry: WorkSafe New Zealand: Energy Safety
Section: 6A
Citation Context:
(2) In these regulations, high-risk prescribed electrical work means the prescribed electrical work (not being low-risk prescribed electrical work) that - (a) comprises or includes the installation, or adjustment of the settings, of any of the following: (i) an extra-low or low voltage installation that does not, or will not, comply with Part 2 of AS/NZS 3000:... ...(d) is work on low voltage AC railway signalling equipment except where the equipment has been tested in accordance with ECP 60 and the work has been carried out in accordance with AS/NZS 3000:...
Ministry: WorkSafe New Zealand: Energy Safety
Section: 78(2)
Citation Context:
Every warrant of electrical fitness for a connectable installation must be issued in accordance with AS/NZS 3001, except that... (c) ...but only after an assessment for compliance with Part 1 of AS/NZS 3000.
Ministry: WorkSafe New Zealand: Energy Safety
Section: Schedule 8, Clause 6
Citation Context:
(2) This clause applies despite anything in Part 1 or 2 of AS/NZS 3000 or in these regulations.
Ministry: WorkSafe New Zealand: Energy Safety
Section: 65
Citation Context:
(1) Every low voltage installation on which prescribed electrical work is done must be tested in accordance with AS/NZS 3000... ...(3) Despite subclause (1), prescribed electrical work done on low voltage AC railway signalling equipment must be tested in
Ministry: WorkSafe New Zealand: Energy Safety
Section: 67(2)
Citation Context:
The following matters may also be confirmed in a certificate of compliance: (a) in relation to a completed new low voltage installation, that- (i) the installation has been installed in accordance with a design prepared in accordance with Part 1 of AS/NZS
Ministry: WorkSafe New Zealand: Energy Safety
Section: 57
Citation Context:
(1) Every installation that operates at low voltage or extra-low voltage must comply with either Part 1 or Part 2 of AS/NZS 3000. (2) A person who installs any part of a low voltage installation must... ...(b) ensure that the installation complies with t
Ministry: WorkSafe New Zealand: Energy Safety
Section: 58
Citation Context:
(1) Every declaration of conformity for a low voltage installation must... ...(b) confirm, in the case of an installation under Part 1 of AS/NZS 3000, that the design complies with regulation 59; and... (3) A declaration of conformity for a revenue meter, if made under this subclause, must— “(a) identify the method of installation to be used; and “(b) confirm that the method complies with Part 1 of AS/NZS 3000; and.... (4) A declaration of conformity signed by a person other than the installer may be treated by the installer as evidence that the design complies with Part 1 or 2 (as appropriate) of AS/NZS 3000.
Ministry: WorkSafe New Zealand: Energy Safety
Section: 72
Citation Context:
(1) A person who inspects prescribed electrical work done on an installation that complies with Part 1 of AS/NZS 3000 must carry out the inspection in accordance with that standard and in accordance with the verification process described in the declarati